Zobrazit stránku 0
Installation Instructions
for 9800 TCNE1 Series Trim by ED5200N (S) (A)
and 9M800 TCNE1 Series Trim by ED5600N (A) with
Rim, SecureBolt™, and Mortise Exit Devices
Important: The accuracy of the door preparation is critical for proper functioning and security of this trim.
Misalignment can cause premature wear and a lessening of security.
Please read these instructions carefully to prevent missing important Steps.
Please Note: Improper installations may result in damage to the lock and void the factory warranty.
FM242B 12/08 (617417610)
1 2 3
4
7
5
8
0
6
9
#
*
For installation assistance contact Corbin Russwin Inc. at 1-800-810-WIRE (9473).
CAUTION
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
TEST
FOR PROPER
OPERATION
BEFORE
CLOSING
DOOR
Zobrazit stránku 0
1 2 3 4 5 6 ... 20 21

Shrnutí obsahu

Strany 1 - Installation Instructions

Installation Instructionsfor 9800 TCNE1 Series Trim by ED5200N (S) (A)and 9M800 TCNE1 Series Trim by ED5600N (A) with Rim, SecureBolt™, and Mortise E

Strany 2 - Table of Contents

6) Installation Instructions (Rim and SecureBolt™)92a.For fire rated devices, feed keypad ribbon cable/connector and ground wire from outside of

Strany 3 - 3) Features / Specifications

6) Installation Instructions (Rim and SecureBolt™)106.6) Installation of Inside Controller Escutcheon and Electrical ConnectionsInsideof DoorKey

Strany 4 - (Rim and SecureBolt™)

11CAUTIO NDOOR MUST REMAIN OPENDURING INSTALLATION .USE DOOR STOP.TESTFOR PROPEROPERATIONBEFORECLOSINGDOOR6) Installation Instructions (Rim and Secure

Strany 5 - 5) Switch Settings

7) 9M800 TCAC1 Series Trim Product Illustration (Mortise)12SolenoidWireHarness“B”“A”“B”“A”GroundWire8 Pin MolexDoorwire2 PinMethodeSolenoid2 PinMolex

Strany 6 - (2) required

7) Installation Instructions (Mortise)13Fire Stop Plate7/8"1-1/21/8" Dia. holes(2) requiredSlotAttach Fire Stop Plate using self tapping scr

Strany 7 - Check cylinder components

Insideof Door(2) #12x1" long flathead combination screw.Mortise Lock7) Installation Instructions (Mortise)147.3) Install Mortise Lock1. Feed So

Strany 8 - (2) 1/4 - 20 Oval

7) Installation Instructions (Mortise) 157.4) Installation of Outside Trim and Exit DeviceOutside Trim AssemblyCoverSolenoidWire Harness“B”“A”“B”“A”D

Strany 9

7) Installation Instructions (Mortise) 167.4) Installation of Outside Trim and Exit DeviceExit DeviceCoverSolenoidWire Harness“B”“A”“B”“A”DeviceFinge

Strany 10

7) Installation Instructions (Mortise)17GASKET APPLICATION:Peel off the adhesive protective paper from gasket. Feed Keypad ribbon cable and ground wir

Strany 11 - Electrical Connections

7) Installation Instructions (Mortise)187.6) Installation of Inside Controller Escutcheon and Electrical ConnectionsInsideof DoorKeypad Ribbon C

Strany 12 - 6.7) Cover Installation

1) Warning2) General Description3) Features / Specifications4) Rim & SecureBolt™ TCNE1 Series Product Illustration5) Switch Settings (Rim

Strany 13

19CAUTIO NDOOR MUST REMAIN OPENDURING INSTALLATION .USE DOOR STOP.TESTFOR PROPEROPERATIONBEFORECLOSINGDOOR6) Installation Instructions (Mortise)7.7)

Strany 14 - 7.1) Before Starting

20Corbin Russwin, Inc. Technical Product Support:Corbin Russwin, Inc.Phone 800-810-WIRE (9493)225 Episcopal RoadBerlin, CT 06037-4004www.corbinrusswin

Strany 15 - 7.3) Install Mortise Lock

2 General Description 2) General DescriptionsThe Access 800® TCNE1 Rim, SecureBolt™ and Mortise Exit Device offers the ability to seamlessly integr

Strany 16 - Wire Harness

34) 9800 TCNE1 Series Trim Product Illustration (Rim and SecureBolt™)SecureBolt™ ShownTailpiecemust bein verticalpositionTrimGasketInsideofDoorCover(2

Strany 17

45) Switch Settings (Rim, SecureBolt™ and Mortise)Switch Settings This device has been shipped from the factory with switch settings configuredas foll

Strany 18 - (optional)

Verify hand and bevel of door. Door should be fitted and hung.Verify box label for size of exit device, function and hand. 6) Installation Instruction

Strany 19

1. Check cylinder components. NOTE: Cylinders longer than 1-1/8" (29mm) will require collars. Refer toCylinder Collar Chart below.2. When r

Strany 20 - 7.7) Cover Installation

6) Installation Instructions (Rim and SecureBolt™) CoverTrim AssemblyTailpiecemust bein verticalpositionBCAA(2) Finish WashersHead ScrewsBSolenoid Wir

Strany 21

6) Installation Instructions (Rim and SecureBolt™) CoverTrim AssemblyTailpiecemust bein verticalpositionBCAA(2) Finish WashersHead ScrewsBSolenoid Wir